Should be used in any application where a surface area is more than 144 square feet. The wide flange allows for more "keying" of the stucco. The "eyebrows" allow for the stucco to key to the "V". Vertical joints should be attached to a stud where necessary.
Control Joints shall be Plastic Components, Inc. #_______. All exterior accessories shall be of PVC material conforming to ASTM standards D1784, C1063 and D4216-99. They shall be used where specified by the architect and installed per industry standards.
"V" control joint, 4-1/8" (111 mm) overall width with perforated flanges.
35
2050
1/2" (13 mm)
35
2058
5/8" (16 mm)
35
2075
3/4" (19 mm)
30
2078
7/8" (22 mm)
25
2100
1" (25 mm)
20
10' (3 m) lengths
Caulk all butt joints, intersections and ends.
It is recommended that PVC products be used for all exterior exposures.
Floor Line Control Bead w/Drip Edge
For use as a horizontal control joint and a moisture control device where two dissimilar materials, such as wood and concrete, meet. (e.g. First floor concrete block construction and wood frame second floor). It allows moisture to migrate away from the wall. The unique drip edge prevents migrating moisture from entering the v-groove of the control joint.
Floor Line Control Bead w/Drip Edge shall be Plastic Components, Inc. #________. All exterior accessories shall be of PVC material conforming to ASTM standards D1784, C1063, and D4216. They shall be used where specified by the architect and installed per industry standards.
Control Bead w/Drip Edge3-1/2" (89 mm) unpunchednailing flange
15
2078-58
5/8" (16 mm)
15
10' (3 m) Lengths
Caulk all butt joints, intersections and ends.
It is recommended that PVC products be used for all exterior exposures.
Factory Assembled Intersections for Floor Line Control Bead
Factory Assembled Intersections for Floor Line Control Bead reduce labor in the field and provide a better quality finish.
Factory Assembled Intersections for Floor Line Control Bead shall be Plastic Components Inc. #_____. All exterior accessories shall be of PVC material conforming to ASTM standards D1784, C1063 and D4216. They shall be used where specified by the architect and installed per industry standards.
Factory Assembled Inside and Outside Corner Intersections, 7/8" (22 mm) Floor Line Control Bead.
15
2078-50AOC
7/8" (22 mm) x 1/2" (13 mm)
15
2078-50AIC
7/8" (22 mm) x 5/8" (16 mm)
15
2078-58AOC
7/8" (22 mm) x 5/8" (16 mm)
15
Caulk all butt joints, intersections and ends.
It is recommended that PVC products be used for all exterior exposures.
Inside Corner Control Joint
Inside Corner Control Joint relieves stress and cracking caused by expansion and contraction in the inside angles of walls and ceilings.
Inside Corner Control Joint shall be Plastic Components Inc. #_____. All exterior accessories shall be of PVC material conforming to ASTM standards D1784, C1063 and D4216. They shall be used where specified by the architect and installed per industry standards.
Caulk all butt joints, intersections and ends.
It is recommended that PVC products be used for all exterior exposures.
Factory Assembled Intersections "V" Control Joint
Use to reduce labor in the field and provide a better quality finish.
Control Joint Intersections shall be Plastic Components Inc. #_____. All exterior accessories shall be of PVC materials conforming to ASTM standards D1784, C1063 and D4216. They shall be used where specified by the architect and installed per industry standards.