Continuous Soffit Vent 2-5/8", 3", 4" and 6" vents

Application
Designed specifically for sheathing products. Has a built-in stop (1/8"-3 mm) to assure proper base thickness as well as maintaining a clean finish edge. The stop flange is serrated for positive material bond. Will not rust, excellent paint adhesion. Connector clips are provided to eliminate sagging at butt joints. Vent holes 1/8" (3 mm) diameter.

Specification
Soffit Vent shall be Plastic Components Inc. #_________. All exterior accessories shall conform to ASTM standards D1784, C1063 and D4216-99. They shall be used where specified by the architect and installed per industry standards.

 
Download PDF InstructionsDownload Installation Instructions Download PDF Data SheetDownload Data Sheet Download CAD DrawingDownload CAD Drawing

548-382-5/8" (67 mm) vented area. Use with any sheathing product. 14 sq. in. (9,033 sq. mm) of free air flow per linear ft.3/8" (10 mm)2-5/8" (67 mm)13
548-501/2" (13 mm)13
548-585/8" (16 mm)13
548-753/4" (19 mm)13
3548-503" (76 mm) vented area. Use with any sheathing product. 15 sq. in. (9,678 sq. mm) of free air flow per linear ft.1/2" (13 mm)3" (76 mm)13
3548-585/8" (16 mm)13
4548-504" (102 mm) vented area. Use with any sheathing product. 16 sq. in. (10,323 sq. mm) of free air flow per linear ft.1/2" (13 mm)4" (100 mm)13
4548-585/8" (16 mm)13
6548-506" (152 mm) vented area. Use with any sheathing product. 18 sq. in. (11,614 sq. mm) of free air flow per linear ft.1/2" (13 mm)6" (152 mm)10
6548-585/8" (16 mm)10
548-HI2-5/8" (67 mm) vented area. Use with any sheathing product. 14 sq. in. (9,033 mm) of free air flow per linear ft. 13
10' (3 m) lengths - Connector clips included.

All butt joints, intersections and ends shall be caulked at the time of installation using an elastomeric sealant, such as Plastic Components' Ultra-TechT (PC-ULTW).

It is recommended that PVC products be used for all exterior exposures.

2-Piece Soffit Vent w/90 Leg

Application
Designed for use with sheathing products. For use when a horizontal soffit and a vertical plan intersect. Vent holes 1/8" (3 mm) diameter. Attach the F-clip to either the vertical fascia board or intersecting vertical wall with the wide flange of the F-clip extending downward, then insert the perforated vent into the F-clip.

Specification
Soffit Vent shall be Plastic Components Inc. #_________. All exterior accessories shall conform to ASTM standards D1784, C1063 and D4216-99. They shall be used where specified by the architect and installed per industry standards.

 

Click To Enlarge
Download PDF InstructionsDownload Installation Instructions Download PDF Data SheetDownload Data Sheet Download CAD DrawingDownload CAD Drawing Download CAD Drawing in PDF format Download PDF Format CAD

F548-38 WF5512-5/8" (67 mm) wide vented area3/8" (10 mm)13
F548-50 WF5511/2" (13 mm)13
F548-58 WF5515/8" (16 mm)13
F548-75 WF5513/4" (19 mm)13
F3548-50 WF5513" (76 mm) wide vented area1/2" (13 mm)13
F3548-58 WF5515/8" (16 mm)13
F4548-50 WF5512-5/8" (67 mm) wide vented area1/2" (13 mm)13
F4548-58 WF5515/8" (16 mm)13
F6548-50 WF5512-5/8" (67 mm) wide vented area1/2" (13 mm)10
F6548-58 WF5515/8" (16 mm)10
10' (3 m) lengths - Connector clips included. Check with customer service for custom sizes.

All butt joints, intersections and ends shall be caulked at the time of installation using an elastomeric sealant, such as Plastic Components' Ultra-TechT (PC-ULTW).

It is recommended that PVC products be used for all exterior exposures.

Surface Mounted Vent 3", 4" and 6" vents

Application
A surface mounted vent suitable for all applications, except stucco. Vent installs easily on all sheathing products with either spray adhesives, or screws. Vent holes 1/8" (3 mm) diameter. For foam applications, a non-solvent base spray adhesive or a 3/4" (19 mm) pin-tac is recommended for attachment. All flanges must be base coated and covered with mesh per system manufacturer.

Specification
Surface Mounted Vent shall be Plastic Components Inc. #_________. All exterior accessories shall conform to ASTM standards D1784, C1063 and D4216. They shall be used where specified by the architect and installed per industry standards.

 

Click To Enlarge
Download PDF Data SheetDownload Data Sheet

SMV31/8" (3 mm) 3" (76 mm) vent area. 15 sq. inches (9,678 sq. mm) free air flow per lineal ft.35
SMV41/8" (3 mm) 4" (102 mm) vent area. 16 sq. inches (10,323 sq. mm) free air flow per lineal ft.35
SMV61/8" (3 mm) 6" (151 mm) vent area. 20 sq. inches (12,904 sq. mm) free air flow per lineal ft.30
10' (3 m) lengths Connector clips included

All butt joints, intersections and ends shall be caulked at the time of installation using an elastomeric sealant, such as Plastic Components' Ultra-TechT (PC-ULTW).

It is recommended that PVC products be used for all exterior exposures.

Clog-free Continuous Soffit Vents

Application
Continuous Soffit Vents have a large 1/4" (6 mm) vent hole configuration that offers excellent air flow and at the same time resists paint clogging. Excellent bond to stucco, also rustproof. Product #300-25 is for installation on soffits where 3/8" sheathing material is used. Product #549-75-25 has a 1" (25 mm) nailing flange for easier installation.

Specification
Soffit Vent shall be Plastic Components Inc. #549-75-25 or #300-25. All exterior accessories shall be of PVC material conforming to ASTM standards D1784, C926, C1063 and D4216. They shall be used where specified by the architect and installed per industry standards.

 

Click To Enlarge

300-253/8" (10 mm)Vent area 2-5/8" (67 mm).25
549-75-253/4" (19 mm)Vent area: 2-3/8" (60 mm)10
10' (3 m) Lengths

All butt joints, intersections and ends shall be caulked at the time of installation using an elastomeric sealant, such as Plastic Components' Ultra-TechT (PC-ULTW).

It is recommended that PVC products be used for all exterior exposures.

Continuous Soffit Vent

Application
Designed specifically for sheathing products. Has a built-in stop (1/8"-3 mm) to assure proper base thickness as well as maintaining a clean finish edge. The stop flange is serrated for positive material bond. Will not rust, excellent paint adhesion. Connector clips are provided to eliminate sagging at butt joints. Vent holes 1/8" (3 mm) diameter.

Specification
Continuous Soffit Vent shall be Plastic Components Inc. #548-HI. All exterior accessories shall conform to ASTM standards D1784, C1063 and D4216. They shall be used where specified by the architect and installed per industry standards and manufacturer's instructions.

 
Download PDF Data SheetDownload Data Sheet

548-58HI2-5/8" (67 mm) wide vented area. Use with any sheathing product. 14 sq. in. (9,033 sq. mm) of free air flow per linear ft. 13
10' (3 m) Lengths Connector clips included

All butt joints, intersections and ends shall be caulked at the time of installation using an elastomeric sealant, such as Plastic Components' Ultra-TechT (PC-ULTW).

It is recommended that PVC products be used for all exterior exposures.
 